SCREENING METHOD ELECTRICAL ONLY COMMERCIAL & COTS MIL-PRF-19500 JAN "S"
Stabilization Bake MIL-STD 750 Method 1032 NO NO Maximum Operating Temperature 340 hours Maximum Operating Temperature 340 hours
Temperature Cycle MIL-STD 750 Method 1051 NO NO 20 Cycles @ -55°C- + 175°C 20 Cycles @ -55°C - + 175°C
Surge MIL-STD 750 Method 4066 NO NO Sinusoidal Current Surge Sinusoidal Current Surge
Thermal Impedance MIL-STD 750 Method 3161 NO NO Delta Source Drain Voltage Method Delta Source Drain Voltage Method
Constant Acceleration MIL-STD 750 Method 2006 NO NO Y Axis 20,000 G's Y Axis 20,000 G's
PIND Test MIL-STD 750 Method 2052 NO NO 20 G's / 40 to 250Hz 20 G's/ 40 to 250HZ
Fine Leak Test MIL-STD 750 Method 1071 Helium Tracer Gas atm cm/3 or greater Condition H 60 PSI pressurization for 4 hours 1X10-9 Condition H 60 PSI pressurization for 4 hours 1X10-9 Condition H 60 PSI pressurization for 4 hours 1X10-9 Condition H 60 PSI pressurization for 4 hours 1X10-9
Gross leak Test MIL-STD 750 Method 1071 Flourocarbon Condition C 60 PSI pressurization for 8 hours Condition C 60 PSI pressurization for 8 hours Condition C 60 PSI pressurization for 8 hours Condition C 60 PSI pressurization for 8 hours
Interim Electrical Test 25°C, + 125°C 25°C, + 125°C 25°C, 125°C, -55°C 25°C, 125°C, -55°C
HTRB MIL-STD 750 Method 1042 80 percent of rated drain to source voltage Steady State Gate bias. NO Condition A/B Steady State reverse bias/ 48 hours Condition A/B Steady State reverse bias/ 160 hours Condition A/B Steady State reverse bias/ 160 hours
Post HTRB Electrical (Delta/PDA) NO Within 96 hours Within 24 hours Within 16 Hours
Burn In MIL-STD 750 Method 1039 Maximum rated power NO 48 Hours 160 Hours 240 Hours
Final Electrical 25°C, 125°C 25°C, 125°C 25°C, 125°C, and -55°C 25°C, 125°C and -55°C
Radiographic Inspection Mil 750 Method 2076 NO NO NO 100 percent